Answer: No, you don't. The seal has 2 small protrusions which interlock with 2 indentations in the groove of the body. This form-fit allows you to install the seal without glue and guarantees a perfect placement.
We use cookies and other tracking technologies to improve your browsing experience on our website, to show you personalized content and targeted ads, to analyze our website traffic, and to understand where our visitors are coming from.
Welcome to the PTD plug diverter valve technical support page. Here you’ll find everything you need to operate, service and maintain your DMN-WESTINGHOUSE PTD plug diverter valve including a service video, manuals, recommended spare parts and answers to frequently asked questions.
Note: Videos are for guidance only. Always follow the official manual and safety instructions.
The video on this page does not replace the operating manual; when in doubt, always consult the official documentation.
Always follow the steps as mentioned in the operating manual and adhere to the safety instructions.
Answer: No, you don't. The seal has 2 small protrusions which interlock with 2 indentations in the groove of the body. This form-fit allows you to install the seal without glue and guarantees a perfect placement.
Answer: Replacing the belly seals is depending on the amount of active running hours. We recommend changing them during every service cycle with, at the minimum, a change every 12 months.
Answer: No, we only have the silicone (static and inflatable) belly seals execution.
Answer: No, you need to remove the bearing cover and arrow assembly from both sides.
Answer: If you have ordered a PTD with the option "inflatable seal ready" you can upgrade the PTD with an upgrade kit to a version with inflatable seals. Please contact our aftersales department for more information.
Answer: Yes, our PTD has several parts we classified as Recommended Spare Parts. We recommend you have these on stock to be used during every service & maintenance cycle. Do you need Spare Parts for your PTD? Please contact our aftersales department.
Answer: Yes, the end covers have threaded holes on either side allowing for a quick switch of the position sensors. For more information please refer to the manual (chapter 10.4.2.7 RELOCATE POSITION SENSOR).
Answer: Please contact our aftersales department for more information regarding the upgrade of a non-ATEX diverter valve to an ATEX certified diverter valve.
Answer: No. Basic tools are sufficient.
Answer: No, this will result in wear on seals and the PTD.